TIME RESOLVED PHOTOSPONSE SYSTEM
TECHNICAL SPECIFICATIONS OF THE TIME-RESOLVED PHOTORESPONSE DEVICE
Ability to measure spectral photoresponse, photosensitivity, and spectral photoconductivity of electronic devices
Wavelength range of the device: 370 nm, 380 nm, 390 nm, 400 nm, 410 nm, 430 nm, 450 nm, 460 nm, 520 nm, 570 nm, 610 nm, 620 nm, 690 nm, 750 nm, 760 nm, 820 nm, 860 nm, 960 nm, 980 nm, 1050 nm, and the ability to add a UV region
Ability to set the optical chopper to all values in the microsecond-second range
The device supports 310 nm, 370 nm, 380 nm, and 390 nm
It should be able to perform the following measurements automatically:
Current-voltage measurements,
Photocurrent-voltage measurements,
Power-voltage measurements,
Photocurrent-wavelength measurements,
InI-voltage measurements,
Wavelength-photocurrent measurements.
The device should automatically measure the following characteristics:
Photocurrent-time characteristics,
Photoresponse-time characteristics,
Photo-acquisition-time characteristics,
Photo-response-time characteristics,
Photo-detection-time characteristics,
Photo-response-time characteristics,
Photo-detection-time characteristics,
at wavelengths of 370 nm, 380 nm, 390 nm, 400 nm, 410 nm, 430 nm, 450 nm, 460 nm, 520 nm, 570 nm, 610 nm, 620 nm, 690 nm, 750 nm, 760 nm, 820 nm, 860 nm, 960 nm, 980 nm, 1050 nm, with the possibility of adding UV wavelengths of 270 nm and 280 nm.
The device should be able to automatically perform the following measurements:
Photocurrent-Wavelength measurements,
Photoresponse-Wavelength measurements,
Photoacquisition-Wavelength measurements,
Photoresponse-Wavelength measurements,
Photodetective-Wavelength measurements.
Photodetective-Wavelength measurements,
with the ability to add UV wavelengths of 270 nm and 280 nm at wavelengths of 370 nm, 380 nm, 390 nm, 400 nm, 410 nm, 430 nm, 450 nm, 460 nm, 520 nm, 570 nm, 610 nm, 620 nm, 690 nm, 750 nm, 760 nm, 820 nm, 860 nm, 960 nm, 980 nm, and 1050 nm.
The device's source meter has a current range of 100 pA-250 mA,
Voltage range: -20V to +20V.
Under sunlight, the device should automatically perform the following measurements in the range of 0-1000 W/m2:
Photoimpedance-Voltage measurements,
Photoadmittance-Voltage measurements,
Photoseries capacitance-Voltage measurements,
Photoparallel capacitance-Voltage measurements,
Photoconductance-Voltage measurements,
Photosusceptance-Voltage measurements,
Photoreactance-Voltage measurements,
Photophase angle-Voltage measurements,
Photoparallel resistance-Voltage measurements,
Photointerface state density-frequency measurements.
The device's impedance analyzer has a frequency range of 125 uHz to 25 MHz and a voltage range of -5 V to +5 V.
The device has an industrial registration certificate.
The device has a 2-year warranty.
The device must be delivered within a maximum of 2 weeks.
Within 1 week of device delivery, at least 3 people must receive at least 30 hours of device maintenance and practical usage training.